PDComm.GemConstantDefinition
Class
Represents one equipment constant to register with GemEquipment.ConfigureConstants.
public sealed record GemConstantDefinitionA list constant cannot have a default, minimum or maximum. The current and default values must lie within the bounds and the count range. The items are only read during configuration; the caller keeps ownership.
Parameters
| Name | Description |
|---|---|
Id | The equipment constant ID (ECID): an ASCII item (case-sensitive, may be empty) or a scalar integer item (I1 to I8 or U1 to U8 with one value). Positive signed and unsigned IDs with the same value are the same ID. |
Name | The constant name (ECNAME); ASCII only, may be empty. |
Units | The units (UNITS); ASCII only, may be empty. |
Current | The initial value (ECV). Its format is the declared format of the constant; later changes must use the same format. JIS-8 items and NaN floating-point values are rejected, also inside lists. |
DefaultValue | The default value (ECDEF), or null when the constant has none. Must have the format of Current. |
Minimum | The lower bound (ECMIN), or null for none. Must have the format of Current. |
Maximum | The upper bound (ECMAX), or null for none. Must have the format of Current. |
MinCount | The smallest element count that a value of the constant may have. |
MaxCount | The largest element count that a value of the constant may have; must not be less than MinCount. |
Members
GemConstantDefinition
Constructor
Represents one equipment constant to register with GemEquipment.ConfigureConstants.
public GemConstantDefinition(SecsItem Id, string Name, string Units, SecsItem Current, SecsItem? DefaultValue, SecsItem? Minimum, SecsItem? Maximum, nuint MinCount, nuint MaxCount)A list constant cannot have a default, minimum or maximum. The current and default values must lie within the bounds and the count range. The items are only read during configuration; the caller keeps ownership.
Parameters
| Name | Description |
|---|---|
Id | The equipment constant ID (ECID): an ASCII item (case-sensitive, may be empty) or a scalar integer item (I1 to I8 or U1 to U8 with one value). Positive signed and unsigned IDs with the same value are the same ID. |
Name | The constant name (ECNAME); ASCII only, may be empty. |
Units | The units (UNITS); ASCII only, may be empty. |
Current | The initial value (ECV). Its format is the declared format of the constant; later changes must use the same format. JIS-8 items and NaN floating-point values are rejected, also inside lists. |
DefaultValue | The default value (ECDEF), or null when the constant has none. Must have the format of Current. |
Minimum | The lower bound (ECMIN), or null for none. Must have the format of Current. |
Maximum | The upper bound (ECMAX), or null for none. Must have the format of Current. |
MinCount | The smallest element count that a value of the constant may have. |
MaxCount | The largest element count that a value of the constant may have; must not be less than MinCount. |
Current
Property
The initial value (ECV). Its format is the declared format of the constant; later changes must use the same format. JIS-8 items and NaN floating-point values are rejected, also inside lists.
public SecsItem Current { get; init; }DefaultValue
Property
The default value (ECDEF), or null when the constant has none. Must have the format of Current.
public SecsItem? DefaultValue { get; init; }Id
Property
The equipment constant ID (ECID): an ASCII item (case-sensitive, may be empty) or a scalar integer item (I1 to I8 or U1 to U8 with one value). Positive signed and unsigned IDs with the same value are the same ID.
public SecsItem Id { get; init; }MaxCount
Property
The largest element count that a value of the constant may have; must not be less than MinCount.
public nuint MaxCount { get; init; }Maximum
Property
The upper bound (ECMAX), or null for none. Must have the format of Current.
public SecsItem? Maximum { get; init; }MinCount
Property
The smallest element count that a value of the constant may have.
public nuint MinCount { get; init; }Minimum
Property
The lower bound (ECMIN), or null for none. Must have the format of Current.
public SecsItem? Minimum { get; init; }Name
Property
The constant name (ECNAME); ASCII only, may be empty.
public string Name { get; init; }Units
Property
The units (UNITS); ASCII only, may be empty.