pdcomm::GemAlarmInfo
Struct
One alarm of the equipment's alarm store, returned by GemEquipment::alarmAt().
struct GemAlarmInfoMembers
active
Field
true while the alarm is set.
bool activecategory
Field
Alarm category, 1 to 63.
uint8_t categoryclearEvent
Field
CEID for the clear transition.
uint32_t clearEventclearEventPresent
Field
true when #clearEvent is configured.
bool clearEventPresentenabled
Field
true when the host enabled reporting of this alarm.
bool enabledid
Field
Alarm ID (ALID).
uint32_t idsetEvent
Field
CEID for the set transition.
uint32_t setEventsetEventPresent
Field
true when #setEvent is configured.
bool setEventPresenttext
Field
Alarm text (ALTX).
std::string text